RMCARD 205/305 Firmware Version 1.4.4 (US Release Date: 4/17/2025)
New Features
- Adds support for Restful API.
- Adds the option for individual bank control functionality on select UPS models.
- Provides support for Modbus TCP function with Accessory/Environmental sensor.
- Now includes support for the manual setting of the Replacement Notification Cycle.
Feature Improvements
- Adds a Radius Server timeout setting in the Command Line Interface (CLI).
- The Over Discharge Protection in [UPS->Configuration] has been optimized to activate only when the UPS supports the Remaining Runtime functionality.
Fixes
- Resolves an issue where the card failed to establish an HTTPS connection with “TLS_DHE” ciphers.
- Fixes an issue where setting the IPv6 Syslog address before IPv4 causes the IPv4 server to miss the syslogs.
- Corrects the problem where the Battery Status, in PowerPanel Business (PPB) Remote, continuously displays “Battery is under quick battery test processing” and the battery test isn’t running.
- Resolves an issue when the Radius server is unavailable, Local accounts cannot log in using the Local+Radius login method.
- Fixes a problem where the system will reboot if the snmpbulkget command, in net-snmp, is executed without providing an OID.
- Updated to fix an issue where the Authentication Type in the “radius pri/sec show” command output, of the Command Line Interface (CLI), is displayed incorrectly.
- Solves an issue where the graphing function is unable to plot the Phase Load and Output Voltage for a Three-phase UPS.
- Fixes a problem where the Graph Data on the [Log->Graphing] webpage appears empty when the environmental sensor is connected to the RMCARD in an ATS PDU.
- Updated to resolve an issue with the value of Source Phase Synchronization, for an ATS PDU, is displayed incorrectly in PowerPanel Business (PPB).
- It fixes a problem where the card failed to navigate to the webpage after updating the accessory firmware when the HTTP/HTTPS port is not set to the default.
- Resolves an issue where the unassigned outlet LED on the [Summary] webpage was not hidden.
- Corrects an issue with the outlet username being displayed incorrectly on the Outlet User Login/Logout event logs.
- Fixes an issue where an error message may not be displayed when a configuration fails on the [System->Security->RADIUS Configuration] webpage.
- Resolves an issue with the table height on the [Log->Energy Records] webpage being displayed incorrectly.
Questions? Contact Tech Support Monday through Friday from 7am– 6pm cst.
Download link and release notes are available here:
https://wp-dev.cyberpowersystems.com/products/software/firmware/